Attenuation measurement is carried out on the installed cable section by means of a stabilized light source and a power meter. Transmission is measured in both directions, at both 1310 and 1550nm.
The connectors must be cleaned thoroughly before connecting the fibers and taking readings, since a dirty connector can affect the reading significantly
The connection of a stabilized light source and
power meter for determining the reference value.
The connectors must be cleaned thoroughly before connecting the fibers and taking readings, since a dirty connector can affect the reading significantly
To prevent the light
sources connector from becoming worn out, a dual connector patch cord should be
connected to the output of the light source the other end of the patch cord
should be provided with a bushing. The patch cord must remain connected to the
light source for the entire period for measurement( removing it might change
the coupling loss readings). Before measurement, the light source and the laser
diode module should be turned on for at least 10 minutes (heating time) to
ensure a stable light flow. Measurements should be carried out with
un-modulated (CW) light.
The light source is placed
at the cables termination point, depending on the direction in which
measurement is to be made. A reference value is then obtained from among five
separate measurements i.e. after connection and disconnection of the bushing.
The second lowest reading
is selected as the reference value. For example, if the following readings were
obtained : -1.82,-2.10,-1.85,-1.92 and –1.88 dBm, -1.85 would be selected as
the reference value.
The power meter is then
shifted to the other end of the cable installation and each fiber is connected
to the transmitter and receiver. Five readings are again taken
When all readings have
been taken the attenuation value for each fiber can be calculated. Only the
second lowest reading is used in this calculation. For example, if the
following readings , -10.56, -10.45, -10.49, -10.66 and –10.37 dBm, were
obtained, the value for the calculation would be –10.45 dBm. The total
attenuation in the fiber is obtained by substracting this value from the
reference value.
Example: (-1.85 – (-10.45) = 8.6 dB.
Setup for measurement the cable attenuation of an operational installation.